DENTSPLY/YORK DIVISION -- BIOBOND II CERAMIC BONDING ALLOY 9456642 -- 6520-00F010656
=====================  Product Identification  =====================

Product ID:BIOBOND II CERAMIC BONDING ALLOY 9456642
MSDS Date:12/11/1987
FSC:6520
NIIN:00F010656
MSDS Number: BHSYX
=== Responsible Party ===
Company Name:DENTSPLY/YORK DIVISION
Address:570 W. COLLEGE AVENUE
City:YORK
State:PA
ZIP:17405
Info Phone Num:(717) 845-7511
Emergency Phone Num:(717) 845-7511
Preparer's Name:ARTHUR P. BURNETT
CAGE:16969
=== Contractor Identification ===
Company Name:DENTSPLY INTERNATIONAL INC
Address:570 WEST COLLEGE AVENUE
City:YORK
State:PA
ZIP:17405
Phone:(717) 845-7511
CAGE:8T797
Company Name:DENTSPLY/YORK DIV/TRUBYTE DIV
Address:570 W COLLEGE AVE
Box:872
City:YORK
State:PA
ZIP:17405-0872
Country:US
Phone:717-845-7511
CAGE:16969

=============  Composition/Information on Ingredients  =============

Ingred Name:NICKEL  (SARA III)
CAS:7440-02-0
RTECS #:QR5950000
Fraction by Wt: 80%
Other REC Limits:1 MG/CUM
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9192

Ingred Name:CHROMIUM  (SARA III)
CAS:7440-47-3
RTECS #:GB4200000
Fraction by Wt: 15%
OSHA PEL:1 MG/M3
ACGIH TLV:0.5 MG/M3; 9192
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:VANADIUM  (SARA III)
CAS:7440-62-2
RTECS #:YW1355000
Fraction by Wt: <5%
Other REC Limits:0.1 MG/CUM
OSHA PEL:C,0.5 MG V2O5/M3 RD
ACGIH TLV:0.05 MG V205/M3;9293

Ingred Name:BERYLLIUM  (SARA III)
CAS:7440-41-7
RTECS #:DS1750000
Fraction by Wt: <2%
OSHA PEL:2 UG/M3
ACGIH TLV:0.002PPM; A2; 9293

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION: HIGH CONCENTRATIONS DUSTS
    MAY CAUSE IRRITATION OF THE THROAT & PULMONARY DISEASE. SKIN:
    SENSITIVITY, DERMATITIS & BURNS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: IN HIGH CONCENTRATIONS DUSTS MAY
    CAUSE IRRITATION OF THE THROAT & CHRONIC PULMONARY DISEASE. SKIN:
    SENSITIVITY, DERMATITIS & BURNS.
Medical Cond Aggravated by Exposure:SENSITIVITY & DERMATITIS

=======================  First Aid Measures  =======================

First Aid:INHALATION: CONTACT PHYSICIAN. SKIN: EYES: FLUSH W/WATER.

=====================  Fire Fighting Measures  =====================

Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:NO SPECIAL PROCEDURES REQUIRED.

======================	Handling and Storage  ======================

Handling and Storage Precautions:THIS MATERIAL SHOULD BE HANDLED & USED
    IN A MANNER CONSISTENT W/THE PRODUCT INSTRUCTIONS.
Other Precautions:USE PROTECTIVE EQUIPMENT WHEN MELTING, CUTTING &
    GRINDING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IN DUSTY AREAS USE NIOSH APPROVED SCHEDULE 21C
    RESPIRATOR.
Ventilation:LOCAL EXHAUST
Protective Gloves:DURING MELTING TO PREVENT BURNS
Eye Protection:DETERMINED BY OPERATION
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Melt/Freeze Pt:M.P/F.P Text:2175F
Spec Gravity:7.81
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SILVERY METALLIC APPEARANCE W/NO ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
MINERAL ACIDS
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:HYDROGEN

====================  Disposal Considerations  ====================

Waste Disposal Methods:NO SPECIAL PRECAUTIONS ARE REQUIRED AS
    BERYLLIUM-NICKEL ALLOYS ARE NOT CLASSIFIED AS HAZARDOUS WASTE UNDER
    THE RESOURCE CONSERVATIONS & RECOVERY ACT. DISPOSE OF WASTE IN
    ACCORDANCE W/FEDERAL, STATE, &  LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.