KOOL MIST CORP. (ALL POWER MFG CO.) -- TAP SUPREME -- 6850-00N008157
=====================  Product Identification  =====================

Product ID:TAP SUPREME
MSDS Date:01/01/1987
FSC:6850
NIIN:00N008157
MSDS Number: BCPNN
=== Responsible Party ===
Company Name:KOOL MIST CORP. (ALL POWER MFG CO.)
Emergency Phone Num:213-802-2640
CAGE:70265
=== Contractor Identification ===
Company Name:KOOL MIST CORP. (ALL POWER MFG CO.)
CAGE:70265

=============  Composition/Information on Ingredients  =============

Ingred Name:METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE)  (SARA III)
CAS:71-55-6
RTECS #:KJ2975000
Fraction by Wt: 95%
OSHA PEL:350 PPM/450 STEL
ACGIH TLV:350 PPM/450STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

Effects of Overexposure:EYE:MILD IRRIT,NO CORNEAL INJURY.SKIN:SHORT
    CONTACT-NO IRRIT.PRLNG/RPTD CONTACT-MINOR (SEE SUPP DATA

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH W/PLENTY OF H*20 FOR @ LEAST 15 MIN.GET MED ATTN.
    INHAL:REMOVE TO FRESH AIR.KEEP WARM & CALM.IF BREATHING STOPS GIVE
    ARTIFICIAL RESPIRATION. INGEST;DO NOT GIVE FLUIDS OR INDUCE
    VOMITING.CAL L PHYSICIAN IMMEDIATELY. SKIN:FLUSH W/H*20.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:NON-FLAMMABLE,NONE
Fire Fighting Procedures:WEAR PRESS DEMAND SCBA & FULL PROTECTIVE
    CLOTHING.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODUCTS MAY INCLUDE
    HCL,PHOSGENE.NOT CONSIDERED FLAM LIQ HAZ UNDER NORMAL CONDITIONS

==================  Accidental Release Measures  ==================

Spill Release Procedures:COVER W/OIL ABSORBENT MATERIAL,SWEEP UP &
    DISPOSE OUTDOORS.LARGE PILLS-EVACUATE AREA.KEEP OUT OF H*20 SUPPLY.

======================	Handling and Storage  ======================

Handling and Storage Precautions:HANDLE WITH REASONABLE CARE.STORE IN
    COOL DRY PLACE.
Other Precautions:NO SMOKING IN AREA OF USE.DONT USE IN GENL VICINITY
    OF ARC WELDING,OPEN FLMS/HOT SURF.HEAT &/OR UV RADIATION MAY CAUSE
    HCL &/OR PHOSGENE FORMATION.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESP PROT DEPENDING ON
    CONDITION OF USE.
Ventilation:LOCAL EXHAUST VENTILATION TO KEEP CONC BELOW TLV.
Protective Gloves:SEE SUPP DATA
Eye Protection:VENTILATED SFTY GLASSES.
Other Protective Equipment:NONE NEEDED.
Supplemental Safety and Health
OVEREXP EFTS:IRRIT/BURN.INHAL:ANESTHETIC EFFECTS MAY OCCUR.INGEST:VERY
    LOW TOXICITY. PROTECTIVE GLOVES:NEOPRENE,POLYETHYLENE.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:165F (74C)
Vapor Pres:100
Vapor Density:4.5
Spec Gravity:1.3
Evaporation Rate & Reference:6.0 (BUTYL ACETATE
Solubility in Water:INSOLUBLE
Appearance and Odor:AMBER LIQUID;MILD ODOR.
Percent Volatiles by Volume:90

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
H/20-SLOW HYDROLYSIS TO GIVE CORROSIVE ACID.
Stability Condition to Avoid:AVOID OPEN FLAMES/SPARKS/HIGH TEMP.
Hazardous Decomposition Products:HCL,TRACES OF PHOSGENE & CL.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE IAW FEDERAL.STATE & LOCAL
    REGULATIONS.USE SOLVENT CONTAINER.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.