MOBIL OIL CORP -- KEROSINE (STOCK: 70.0) -- 9130-00N028229
===================== Product Identification ===================== Product ID:KEROSINE (STOCK: 70.0) MSDS Date:12/08/1989 FSC:9130 NIIN:00N028229 MSDS Number: BQBMT === Responsible Party === Company Name:MOBIL OIL CORP Box:1031 City:PRINCETON State:NJ ZIP:08540 Country:US Info Phone Num:609-737-5596; 800-662-4525 Emergency Phone Num:609-737-4411;800-424-9300(CHEMTREC) Preparer's Name:ENVIRON AFFAIRS/TOX DEPT CAGE:1E969 === Contractor Identification === Company Name:MOBIL OIL CORP Address:530 EAST SWEDESFORD ROAD Box:1031 City:VALLEY FORGE State:PA ZIP:19482 Country:US Phone:703-849-3265 CAGE:1E969 Company Name:MOBIL OIL CORP ENVIRONMENTAL AFFAIRS & TOXICOLOGY Address:PENNINGTON-ROCKY HILL RD Box:City:PENNINGTON State:NJ ZIP:08534 Country:US CAGE:0AHK0 ============= Composition/Information on Ingredients ============= Ingred Name:KEROSENE CAS:8008-20-6 RTECS #:OA5500000 Fraction by Wt: 100% OSHA PEL:100 PPM ACGIH TLV:100 PPM ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50: (ORAL,RAT) >15 G/KG. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:MODERATE EYE IRRITATION. MODERATE SKIN IRRITATION. RESPIRATORY IRRITATION, DIZZINESS, NAUSEA, LOSS OF CONSCIOUSNESS. PROLONGED REPEATED SKIN CONTACT WITH LOW VISCOSITY MATERIALS MAY DEFAT SKIN RESULTI NG IN POSSIBLE IRRITATION AND DERMATITIS. Explanation of Carcinogenicity:NOT RELEVANT. Effects of Overexposure:SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:EYE: FLUSH THORO W/H*2O FOR AT LEAST 15 MIN. GET MED ASSISTANCE. SKIN: WASH CONT AREAS W/SOAP & H*2O. INHAL: REMOVE FROM FURTHER EXPOS. IF UNCON OCCURS, SEEK IMMED MED ASSISTANCE & CALL PHYS. IF BRTHG HAS STOPPED, USE MOUTH TO MOUTH RESUSCITATION. INGESTION: NOT EXPECTED TO BE PROBLEM WHEN INGESTED. IF UNCOMFORTABLE SEEK MED ASSISTANCE. (NOTE TO PHYS: MATL IS ASPIR INTO LUNGS MAY CAUSE (SUPP DATA) ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:>100F,>38C Lower Limits:0.7% Upper Limits:5.0% Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL AND WATER FOG. Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.USE H*2O TO KEEP FIRE EXPOS CNTNRS COOL.IF LEAK/SPILL HAS NOT IGNITED,USE H*2O SPRAY TO DISPERSE (SUPP DATA) Unusual Fire/Explosion Hazard:MATERIAL IS COMBUSTIBLE. ================== Accidental Release Measures ================== Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED SAWDUST, DIATOMACEOUS EARTH, ETC. SHOVEL UP AND DISP OF AT AN APPROPRIATE WASTE DISP FACILITY I/A/W CURRENT APPLICABLE LAWS & REGS, AND PROD CHARACTERISTICS AT TIME OF DISPOSAL. REPORT SPILLS AS REQD TO APPROP AUTH. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN A COOL AREA. AVOID CONTACT WITH EYES. AVOID CONTACT WITH SKIN. Other Precautions:NONE SPECIFIED BY MANUFACTURER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATORY PROTECTIVE EQUIPMENT MUST BE USED IN HIGH VAPOR OR MIST CONCENTRATIONS. Ventilation:USE IN WELL VENTILATED AREA. EQUIPMENT SHOULD BE EXPLOSION PROOF. Protective Gloves:IMPERVIOUS GLOVES. Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS BE FOLLOWED. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. Supplemental Safety and Health FIRE FIGHT PROC: VAPS & TO PROT MEN ATTEMPTING TO STOP LEAK. H*2O SPRAY MAY BE USED TO FLUSH SPILLS AWAY FROM EXPOS. PREVENT RUNOFF FROM FIRE CONTROL OR DILUTION FROM ENTERING STREAMS OR DRINKING WATE R SUPPLY. FIRST AID PROC: CHEMICAL PNEUMONITIS. TREAT APPROPRIATELY.) ================== Physical/Chemical Properties ================== HCC:F4 Boiling Pt:B.P. Text:>320F,>160C Melt/Freeze Pt:M.P/F.P Text:-60F,-51C Vapor Pres:<1.0 @ 20C Vapor Density:0.825 Solubility in Water:NEGLIGIBLE Appearance and Odor:CLEAR LIQUID, MILD ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZERS. Stability Condition to Avoid:HEAT, SPARKS, FLAME AND BUILD UP OF STATIC ELECTRICITY. Hazardous Decomposition Products:CARBON MONOXIDE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF WASTE BY SUPERVISED INCINERATION IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.